09 Maintenance
44
User Manual V1.2-2025-01-16
No. Fault Cause Solutions
41
PV String
Reversed
(Str1~Str16)
The PV string is
connected reversely.
Check if The PV string is connected
reversely.
42 PV voltage Low
Sun light is weak or
changing abnormally.
1. If the problem occurs occasionally, the
reason might be abnormal sun light. The
inverter will recover automatically without
manual intervention.
2. If the problem occurs frequently,
contact the dealer or the after-sales
service.
43 BUS voltage Low
44
BUS Soft Start
Failure
boost driving ciucuit is
abnormal.
Disconnect the AC output switch and
DC input switch, then connect them 5
minutes later. Contact the dealer or the
after-sales service if the problem persists.
45
BUS Voltage
Imbalance
1. Abnormal inverter
sampling circuit
2. Abnormal hardware.
46
Gird Phase Lock
failure
the grid frequency is
unstable.
47
Inverter
Continuous
Overcurrent
Short time sudden
changes in the grid or
load cause the control
overcurrent.
If the problem occurs occasionally, ignore
it. If the problem occurs frequently,
contact the dealer or the after-sales
service.
48
Inv Software
Overcurrent
49
R Phase Hardware
Overcurrent
50
S Phase Hardware
Overcurrent
51
T Phase Hardware
Overcurrent