Goodwe GW50K-SDT-C30 handleiding

127 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 17 van 127
03 Product Introduction
13
24h Load Monitoring (Optional)
The smart meter measures the data of the grid side and transmits it to the
inverter.The inverter transmits the grid side data and the power generation
data to the monitoring platform via a communication module, and then moni-
toring platform calculates the load power consumption, thus realizing the 24h
load monitoring.
5-29.9kW(AU), GW25K-SDT-30, GW30K-SDT-30 (standard), others (optional).
When the PV modules stop working due to insu󽗋cient sunlight at night, the
inverter can take power from the grid side to maintain basic functions (such
as monitoring, communication, safety module) and achieve functions such as
24h load monitoring, night monitoring and remote upgrading at night.
The inverter supports parameter setting via WiFi or Bluetooth in the near
proximity. It also supports connecting to the monitoring platform via WiFi,
4G or LAN, so as to monitor the operation status of the inverter, the operation
conditions of the power station, etc.
Bluetooth: meets Bluetooth 5.1 standard.
WiFi: wireless IEEE 802.11 - b/g/n @2.4 - GHz.
LAN: Ethernet with 10M/100Mbps adaptive speed. If a third-party
monitoring platform is to be used, this platform must support the
ModbusTCP communication protocol.
4G: It supports connection to a third-party monitoring platform via the
MQTT communication protocol.
Communications
Smart dongle
module
SolarGo App
LAN < 100 m
WiFi < 10 m
Bluetooth < 5 m
SEMS Portal App
Router
Server
4G
WiFi < 10 m
Power Supply at Night (Optional)