06 Electrical Connection
27
User Manual V2.2-2025-07-24
Inverter
PV String
Utility Grid
Loads
Circuit
Breaker
Circuit
Breaker
Meter
NOTICE
After completing cable connections, set related parameters via LCD or SolarGo app to enable
export power limit control or output power limit control.
CT90
HK1000
HK1000
With the HomeKit device and two CTs, the inverter output data and on-grid data can be
accurately measured to calculate the load electricity consumption. The operating data will be
uploaded to the cloud via WiFi or LAN to realize 24 hours real-time load electricity consumption
monitoring.
Load Monitoring Network
Both the current sampling accuracy error margin of CT and the output voltage sampling
accuracy error margin of the inverter are ±1%, so the output power sampling accuracy error
margin of the inverter is ±2%.
Inverter
PV String
Utility Grid
Loads
Circuit
Breaker
Circuit
Breaker
Meter