Goodwe GW10K-MS handleiding
Handleiding
Je bekijkt pagina 14 van 60

03 Product Introduction
10
User Manual V2.2-2025-07-24
24h Load Monitoring (Optional)
The smart meter measures the data of the grid side and transmits it to the inverter. The inverter
transmits the grid side date and the power generation date to the monitoring platform via a
communication module, and then monitoring platform calculates the load power consumption
and the 24H load monitoring is realized.
Power Supply at Night (Optional)
When the PV modules stop working due to insucient sunlight at night, the inverter can take
power from the grid side to achieve functions such as night monitoring and remote upgrading at
night.
The PID function of this inverter operates by elevating the voltage dierential between the PV
panels and their frames to a positive value (termed as positive-voltage elevation). This eectively
suppresses the PID eect and is applicable to P - type PV panels as well as N-type PV panels that
necessitate positive - voltage elevation for PID suppression. For N - type PV panels that demand
negative - voltage reduction to suppress the PID eect, it is advisable to deactivate this function.
Regarding whether an N - type module falls into the category that requires positive - voltage
elevation for PID suppression, please consult the module supplier.
PID Functions
Bekijk gratis de handleiding van Goodwe GW10K-MS, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Goodwe |
| Model | GW10K-MS |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 6944 MB |