● Signal source.
● Fixture’s current DMX address in large characters. If the fixture’s self-diagnosis
system detects an error, the fixture will flash an error message alternately with the
DMX address. This lets you see the DMX address and error message at a distance
from the fixture.
● If the fixture detects a valid, active network at one of the fixture’s etherCON ports, the
default screen will show a network icon to the left or right of the DMX address:
- Icon on left = data at Port A (on left of fixture when facing control panel)
- Icon on right = data at Port B (on right of fixture when facing control panel)
The fixture displays network speed below the network icon.
If the fixture does not detect a network at one of the ports, it displays NO LINK
instead of the network icon for that port.
● Below the current DMX address, the fixture displays in smaller characters the DMX
channels that the fixture is currently using.
In the example shown in Figure 3:
● The fixture is running CPU software version 0.2.2
● The fixture is set to DMX Mode 1
● The fixture is set to receive data via ArtNet
● The fixture’s DMX start address is 001
● The fixture is using DMX channels 1 to 27.
Using the control panel
The four control panel buttons around the display have the following functions
indicated by icons next to them on the display.
In the main screen:
QUICK MENU – Activates the Quick Menu
UP/DOWN – Press three times to open the live diagnostic tool
MENU – Activates the control panel if it is in sleep mode, then
opens the main menu