GLP MAD MAXX handleiding
Handleiding
Je bekijkt pagina 21 van 32

German Light Products GLP MAD MAXX
Rev. 20250625-1 21
6. Connections
Warning! Read ‘Safety’ starting on page 5 before connecting the GLP MAD
MAXX to power.
AC power
The fixture has an IP65-rated Neutrik powerCON TRUE1 TOP (True Outdoor
Protection) socket for connection to AC mains power from a Neutrik powerCON
TRUE1 TOP female cable connector. To maintain the fixture’s IP65 rating, use only this
type of cable connector.
The auto-sensing power supply accepts 180-240 V, 50/60 Hz AC power. Do not
connect the fixture to AC power at any other voltage.
The AC mains power distribution circuit must include a connection to ground /
protective earth. It must be protected against ground / earth leakage and overload.
Do not connect the fixture to a power distribution circuit that is equipped with an
external dimmer.
Powering the fixture on
The fixture does not have an ON/OFF switch. It is powered on as soon as power is
applied to the power input cable. Before applying power, check that the head is
unlocked, check that the head will not collide with anything, and check that nobody
will be looking directly at the fixture if it lights up suddenly.
Connecting to power
Although powerCON TRUE1 TOP connectors support hot-plugging, it is still good
practice to shut down power to power cables before connecting them to fixtures.
To connect the fixture to power:
1. Check that the connector on the power input cable is in perfect condition, paying
attention to the keys on the connector. If the connector or its keys show signs of
damage, replace the connector with a new item.
Figure 6. Mains power IN socket
Bekijk gratis de handleiding van GLP MAD MAXX, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | GLP |
| Model | MAD MAXX |
| Categorie | Verlichting |
| Taal | Nederlands |
| Grootte | 4369 MB |