GLP JDC1 handleiding

76 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 8 van 76
www.glp.de
8 JDC1 User Manual Rev. 20240830-01
Provide well-lit conditions to reduce the pupil diameter of anyone working on or
near the product.
Strobe safety
Flashing light, particularly at 5 - 30 Hz, may cause seizures in persons with
photosensitive epilepsy. Do not use strobe effects for extended periods.
Comply with local regulations on the use of strobe lighting and notify the public in
advance with highly visible warning signs when strobe effects are used.
If a seizure occurs, stop using strobe effects. Seek professional medical help. Note
the time that the seizure starts and finishes. Call emergency medical help urgently if
the seizure lasts more than five minutes, if it is the person’s first seizure, or if the person
is injured. While waiting for help to arrive, consider the following general advice for
caring for a person who is having a seizure: Protect the affected person from injuring
themselves on hard or sharp objects. If necessary, move the person to a safe place.
Lay them on their side with their head supported to prevent it from hitting the floor.
Loosen any tight clothing around their neck. Do not use force to hold the person or
restrict their movements. Do not put anything in their mouth, including your fingers.
Installation safety and protection from personal injury
Installation must be performed by qualified personnel only and carried out in
accordance with applicable regulations such as DIN VDE 0711-217.
The product is not portable when installed.
Ensure that the supporting structure and installation hardware used can hold at least
10 times the weight of the load that they support.
Suspend the product with hardware specifically designed and rated for the
purpose. Check that the hardware is in perfect condition. Fasteners must be steel
grade 8.8 strength or better. Rigging clamps must be half-coupler type that
completely encircle the rigging truss chord.
Screws or bolts used for mounting hardware must protrude minimum 9 mm / 0.36 in.
and maximum 11 mm / 0.43 ins. into the threaded holes in the base of the fixture.
If the product is installed in a location where it may cause injury or damage if it falls,
install as directed in this manual a safety cable or similar secondary attachment that
will hold the product if a primary attachment fails. The secondary attachment must
be approved by an official body such as TÜV as a safety attachment for the weight
that it secures, it must comply with EN 60598-2-17 Section 17.6.6, and it must be able
to support a static suspended load that is ten times the weight that it secures.