GLP impression X5 IP handleiding
Handleiding
Je bekijkt pagina 32 van 41

www.glp.de X5 IP
32 impression X5 IP User Manual
These settings will not be affected if you apply a Load Default Settings command
in the fixture’s control panel, but they will be returned to factory defaults if you
apply a Load Factory Backup command in the fixture’s control panel.
Note that it is possible to transmit DMX data as broadcast or unicast packages via
Art-Net. If a large number of universes (more than 30) is broadcast, data loss can
occur. If you suspect that this is happening, configure your console to unicast Art-
Net DMX packages to fixtures, or switch to sACN.
sACN
To configure the fixture to receive DMX control data via sACN, open the menus in
the fixture’s control panel and make the following settings:
In the first menu (root menu), give a suitable DMX address to the fixture.
In the Protocol Setup → Protocol Type menu, set the control protocol to sACN.
Give all fixtures their own unique IP addresses. To do this, you can either:
● set fixtures to generate their own IP addresses by choosing the ranges 2.x.x.x or
10.x.x.x (Art-Net specification),
● set fixtures to acquire IP addresses automatically by DHCP, or
● assign IP addresses manually by entering individual IP addresses and Subnet
mask.
Select an sACN universe from 00001 to 63999.
These settings will not be affected if you apply a Load Default Settings command
in the fixture’s control panel, but they will be returned to factory defaults if you
apply a Load Factory Backup command in the fixture’s control panel.
iQ.Mesh
To set up the fixture for control via GLP iQ.Mesh:
Open the menus in the fixture’s control panel.
In the Protocol Setup → Data In menu, set the control protocol to iQ.Mesh.
LumenRadio CRMX
Note: The impression X5 IP is supplied as standard with a LumenRadio CRMX
module installed in the fixture’s FPO port. The CRMX control option is only available
with this module installed.
To set up the fixture for control via LumenRadio CRMX:
Open the menus in the fixture’s control panel.
In the Protocol Setup → Data In menu, set the control protocol to CRMX.