Setting up the control protocol
The impression X5 IP can be controlled using:
● USITT512 DMX over a standard DMX cable link using the fixture’s 5-pin XLR
connectors
● DMX via Art-Net or sACN using one of the fixture’s two Ethernet ports
● GLP’s wireless iQ.Mesh technology
● LumenRadio CRMX. The integrated GLP FPO (Flexible Protocol Option) port
allows the installation of an additional protocol module. The fixture is supplied
with a LumenRadio CRMX module installed in the FPO port as standard.
This section explains how to configure the fixture to use one of these control data
protocols.
Note: The control protocol settings are not affected if you apply a Fixture Settings
→
Load User Settings
→
Setting Defaults command in the fixture’s control panel,
but they are returned to factory defaults if you apply a Load Factory Defaults
command in the main menu.
DMX
The fixture is set up for control via a standard DMX cable link by default.
If the control data protocol has been changed and you want to return to DMX
control over a standard DMX cable link:
Open the menus in the fixture’s control panel.
In the main menu, open DMX Address and give the fixture a suitable DMX
address.
In the Protocol Setup → Data In menu, set the control protocol to DMX.
Art-Net
To configure the fixture to receive DMX control data via Art-Net, open the menus in
the fixture’s control panel and make the following adjustments:
In the first menu (root menu), give a suitable DMX address to the fixture.
In the Protocol Setup → Protocol Type menu, set the control protocol to Art-
Net.
Give all fixtures their own unique IP addresses. To do this, you can either:
● set fixtures to generate their own IP addresses by choosing the ranges 2.x.x.x or
10.x.x.x (Art-Net specification),
● set fixtures to acquire IP addresses automatically by DHCP, or
● assign IP addresses manually by entering individual IP addresses and Subnet
mask.
Select an Art-Net port/universe from 00000 (Network 0 / Subnet 0 / Universe 0)
to 32767 (Network 7 / Subnet 15 / Universe 255). Note that the first Art-Net
universe is considered to be universe number 00000, not 00001.