German Light Products® X5 Bar 1000
Rev. 20240207-01 25
Test LED: Runs a test sequence of the LED pixel only. Press BACK to stop the test
sequence.
Test Zoom: Runs a test sequence of Zoom functionality only. Press BACK to stop the
test sequence.
Test Fans (Auto): Starts a fan self-test. Tries to detect fan errors, clears any current
errors if successful.
Test Fans (Manual): Tests fans one by one manually.
Test Encoders: Auto test for all encoders.
Advanced Service
The Advanced Service level is for trained technicians only. Read the information below
carefully before entering this level. You must confirm by pressing and holding ENTER for
3 seconds before you can enter this level.
The Advanced Service level contains the following items:
Service Mode: Disables tilt and all display timeouts to make servicing the fixture
head easier. This mode is automatically disabled after a power cycle.
Job Offset: Lets you set +/- offsets on mechanical effects. Custom job offsets let you
adjust fixtures in multiple installations (to compensate for the different positions of
fixtures in a rig, for example).
Any custom job offsets that you create here will not affect the fixture’s effect
calibration.
All custom job offsets created here are deleted if you apply a Load Factory
Defaults command.
Reset Counters: Resets the different resettable fixture counters.
Device counters are not reset by a Load Factory Backup command.
Save User Settings: Lets you save the current fixture settings to one of the three user
settings presets. You can load a user settings preset that you have saved with a
Load User Settings command (see Fixture Settings Load User Settings). The default
fixture preset cannot be changed.
This command only saves fixture settings (Fan Mode, Color Mix etc.). It does not
save fixture configuration information such as DMX address and DMX mode.
Firmware Push (Fixture2Fixture): Pushes the fixture’s firmware (flash storage) to all
other fixtures of the same type via the DMX link.
Important! The impression X5 Bar 1000 series firmware is fully compatible with all
impression X5 series fixtures. This means that a firmware push carried out by an
impression X5 Bar 1000 will also push its firmware to other impression X5 fixtures such
as impression X5, impression X5 Compact, impression X5 Bar 1000 etc.