Fan modes
The four different cooling fan modes give you a range of options to choose from
depending on how you want to allocate priority between high-intensity light output or
low fan noise:
• Fan regulated gives priority to light output and only operates fans as necessary. If the
fixture is blacked out, fans run at minimum speed. When light output intensity is
increased, temperature regulation increases fan speed to the level necessary to keep
the fixture at optimum temperature.
If light output is set to maximum intensity but the fans can keep the fixture at optimum
temperature, there will be no regulation of light intensity. If the fixture begins to
exceed optimum temperature, light intensity will be limited until optimum
temperature can be maintained.
• Fan constant high mode is optimized for maximum light output and suits operation in
high ambient temperatures. Fans are set to constant operation at high speed. Light
output intensity is limited smoothly if it becomes necessary in order to keep fixture
temperature at optimum level.
Besides maximizing light output in high ambient temperatures, you can use this mode
to cool down a fixture quickly or to remove dust from cooling fans.
• Fan constant medium sets fans to constant operation at medium speed. Light output
intensity is reduced to a level where it will normally remain constant at ambient
temperatures of up to 45° C (113° F). Intensity is smoothly limited further if it becomes
necessary in order to keep fixture temperature at optimum level.
• Fan constant low mode sets fans to constant operation at low speed and is optimized
for minimum noise. Light output intensity is reduced to a level where it will normally
remain constant at ambient temperatures of up to 30° C (86° F). Intensity is smoothly
limited further if it becomes necessary in order to keep fixture temperature at
optimum level.
In all fan modes, if fixture temperature reaches a dangerous level, LEDs will be shut
down for a period until the fans have brought the temperature down to a safe level.
You can set the cooling fan mode using the control panel or the Special/Control DMX
channel.
Performance settings
You can select between three different settings for the movement speed of all the
fixture’s mechanical effects (pan/tilt, color wheel, zoom, focus, etc.):
• In Normal mode, mechanical effects movement is set to give an optimum balance
between speed, quietness and smoothness. Normal is the default setting.
• In Fast mode, movement is set to maximum speed. This setting gives super-fast effects
but can result in higher noise levels.
• In Smooth mode, movement is set to optimize smoothness and give lowest-noise
performance. This setting gives extremely low noise and smooth performance but
effect movement will be slower than in Normal mode.
You can select Movement Performance using either the control panel or the
Special/Control DMX channel.