German Light Products Settings
Rev. 20240416-1 15
● Low mode sets fans to constant operation at low speed and is optimized for
minimum noise. Light output intensity is reduced to a level where it will normally
remain constant at ambient temperatures of up to 30° C (86° F). Intensity is smoothly
limited further if it becomes necessary in order to keep fixture temperature at
optimum level.
Note: In all fan modes, if fixture temperature reaches a dangerous level, the LEDs are
shut down for a period until the fans have brought the temperature down to a safe
level.
Load User Settings
Lets you load different custom fixture configurations or return the fixture to the default
fixture settings.
To save a custom setting preset from 1 to 3, see Service
Advanced
Save_Settings.
● Load User Settings 1 to 3 loads one of three specific custom fixture settings. You
must confirm the function for 3 seconds before the new settings are loaded (see
Fixture Settings
Load User Settings).
● Save User Settings 1 to 3 saves the current fixture settings as a set of user settings.
You must confirm the function for 2 seconds in order to save the settings as one of
the three custom settings presets (see Service
Advanced
Save User Settings).
Note: The Load User Setting Presets and Load User Setting Defaults commands will
only affect settings in the Fixture Settings group and will not affect DMX Address,
Control Mode, Protocol Type, IP Settings, etc. This helps avoid loss of communication
with the controller.
Manual DMX
Gives individual control of the fixture using the fixture user interface. The menu timeout
function is disabled while this menu is open.
Note that external DMX Values will always have higher priority than manually entered
values. We recommend that you disconnect the fixture from the data source when
using Manual DMX.
Manual DMX values are saved to the internal Scene (Stand Alone) memory as soon you
exit the Manual DMX menu. This scene can be replayed automatically using the No-
Signal Scene (Stand Alone) function.
● Manual Control: Manually sets a DMX value for each function.