www.glp.de Settings
14 Fusion X-PAR 18Z User Manual
● Off: The display will automatically switch off after a few seconds even if the fixture is
not receiving a valid control signal or if it has detected an error. Pressing any button
turns on the display again.
Using the Fixture Settings Display Orientation option you can rotate the display to
make it easier to read if the fixture is rigged upside-down.
Using the Fixture Settings Lock option you can lock the control panel to prevent the
options being changed. To unlock, enter the passcode – the default passcode is 0000 or
you can set your own code using the Fixture Settings Lock Set Passcode menu
setting.
When the display is locked, pressing any button will show a warning message and the
button press will have no other effect.
If the passcode is lost, you can reset it to the default by loading Factory Default Settings
using the DMX Control channel or by RDM.
Fan modes
Four cooling fan modes let you give priority to lowest fan noise or most powerful
cooling:
● Regulated mode gives priority to light output and only operates fans as necessary. If
the fixture is blacked out, fans run at minimum speed. When light output intensity is
increased, temperature regulation increases fan speed to the level necessary to keep
the fixture at optimum temperature.
If light output is set to maximum intensity but the fans can keep the fixture at
optimum temperature, there is no regulation of light intensity. If the fixture begins to
exceed optimum temperature and the fans are running at maximum speed, light
intensity is limited until optimum temperature can be maintained.
● High mode sets the fixture to give maximum light output and suits operation in high
ambient temperatures. Fans are set to constant operation at high speed. Light
output intensity is limited smoothly if it becomes necessary in order to keep fixture
temperature at optimum level.
You can also use High mode to cool down a fixture quickly after a period of operation
or to help remove dust from cooling fans.
● Medium mode sets fans to constant operation at medium speed. Light output
intensity is reduced to a level where it will normally remain constant at ambient
temperatures of up to 45° C (113° F). Intensity is smoothly limited further if it becomes
necessary in order to keep fixture temperature at optimum level.