Electrical safety
• The fixture is IP65-rated. It may be installed in outdoor locations temporarily for
entertainment lighting purposes. It is not designed to be installed permanently
outdoors or in any environment where there is a presence of salt or other
corrosive substance. Do not submerge the fixture or any part of it. Do not expose
any part of the fixture to high-pressure water or air jets.
• Ensure that cables arrive at connectors from below. Ensure that water cannot
pool around connectors.
• Use only a source of AC mains power that complies with local building and
electrical codes and has both overload and ground fault (earth fault) protection.
• Ensure that the fixture is electrically connected to ground (earth).
• Disconnect the fixture from AC mains power before carrying out any installation
or maintenance work and when the fixture is not in use.
• Disconnect the fixture from power immediately if any seal, cover, cable,
connector or other component is damaged, defective, deformed or showing
signs of overheating. Do not reapply power until the fixture has been repaired
and made safe by a technician authorized by GLP.
• Check that all power distribution equipment, cables and connectors are in
perfect condition, rated for the electrical requirements of all connected devices,
suitable for their application and suitable for the installation environment.
• Use only Neutrik PowerCON TRUE1 TOP-type cable connectors for AC mains
power input at the fixture’s Mains IN connector and for relaying AC mains power
from one fixture’s Mains OUT (Thru) connector to another fixture’s Mains IN
connector.
• Use minimum 14 AWG or 1.5 mm
2
power input and relay cables that are
minimum 16 A-rated and temperature-rated to suit the application. In the USA
and Canada the cables must be UL-listed, type SJT or equivalent. In the EU the
cables must be type H05VV-F or equivalent for indoor use in a dry or wet
environment or type H07RN-F or equivalent for outdoor use or use in a location
where the temperature may fall below 5° C / 41° F.
• Do not connect devices to power in a chain if the total maximum current draw of
all the devices in the chain when added together will exceed the current rating of
any cable or connector used at any point in the chain. The supplied power input
cord (cable) is rated as follows:
- US power cord: 16 A, 14 AWG, UL-listed, E304117, SJT, length 4.9 ft.
- EU power cable: 16 A, 1.5 mm², H05VVF-F, length 1.5 m. This cable is suitable for
indoor use in dry or wet locations. If you use the fixture in an outdoor location or
in any location where the ambient temperature can fall below 5° C / 41° F,
replace the power cable with a 16 A-rated, 3 x 1.5 mm
2
H07RN-F type cable.
Do not connect more than two (2) Fusion Creos fixtures linked together in a chain
to power at 100-120 V, 60 Hz.