GLP Fusion Creos handleiding
Handleiding
Je bekijkt pagina 21 van 33

www.glp.de
Rev. 20240917-01 21
7. AC mains power
Warning! Read ‘Safety’ starting on page 5 for important safety
information that you must understand before you install or operate the
fixture.
Check that all cables and connectors are suitable for the installation
environment and application (see recommendations in ‘Avoiding damage to the
fixture’ on page 11).
Cables used for power input and for relaying power to other fixtures must meet the
requirements listed under ‘Electrical safety’ on page 7.
Power input cable
The Fusion Creos is supplied with a power cord (power cable) with a powerCON
TRUE1 TOP connector for AC mains power input.
Connecting to power
The AC mains power supply must include a connection to ground / protective earth.
It must be protected against ground / earth leakage and overload. The fixture’s
internal auto-sensing power supply accepts AC power at 100-240 V, 50/60 Hz. Do
not connect the fixture to power at any other voltage or to an external dimmer.
The Fusion Creos does not have a power ON/OFF switch. Power is applied to the
fixture as soon as the power cable becomes live.
The Fusion Creos has a 3-conductor powerCON TRUE1 TOP Mains IN power input
socket that accepts AC power from a TRUE1 TOP female cable connector. Although
TRUE1 connectors support hot-plugging, it is still good practice to shut down power
to power cables before connecting them to fixtures.
To connect the fixture to power:
If possible, shut down power to the power input cable.
Note the position of the keys and keyways on the TRUE1 TOP power cable
connector and Mains IN socket and align them with each other carefully. Insert
the cable connector into the socket and twist clockwise to lock. Do not use force.
If the connector feels excessively stiff, remove it and check that it is lined up
correctly.
Before applying power to the power cable, check that the tilt lock is released,
that nobody is looking directly into the front of the fixture and that there is no
risk of collision if the head tilts without warning.
To disconnect the fixture from power, pull the latch on the cable connector
outwards to release it, then twist the connector counterclockwise and pull to
remove it from the socket.
Installing power connectors
If you need to replace the cord cap / power plug on the supplied power cord /
power input cable, check that the cord cap / plug is rated minimum 250 V, 16 A, that
it has a connection to ground / earth and that it has an integral cable grip. Follow
the cord cap / plug manufacturer’s assembly instructions.
Bekijk gratis de handleiding van GLP Fusion Creos, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | GLP |
| Model | Fusion Creos |
| Categorie | Verlichting |
| Taal | Nederlands |
| Grootte | 5720 MB |