www.glp.de DoP Converter DINrail / UM
14 GLP DoP Converter User Manual Rev. 20220320-01
6. Connecting to AC mains power
Warning! Read ‘Safety’ starting on page 4 for important safety information
that you must understand before you install or operate the fixture.
Check that all cables and connectors are suitable for the installation
environment and application.
Provide supports to carry the weight of all cable runs. Do not allow the
weight of cables to hang from screw terminals, as this may pull cables out of
the terminals and create a risk of serious or lethal electric shock.
The AC mains power supply must be protected against ground / earth leakage and
overload. The DoP Converter’s internal power circuits accept AC power at 100-240 V,
50/60 Hz. Do not connect the Converter to power at any other voltage or to an
external dimmer.
All DoP Converters are class II protected and do not require a ground / protective
earth connection.
The DoP Converter does not have a power ON/OFF switch. Power is applied to the
Converter as soon as a power cable connected to the Converter becomes live.
The voltage at the DoP Converter’s mains power throughput terminals is the same as
that at the input terminals.
DoP Converter DINrail
The DoP Converter DINrail does not have ground / earth connection terminals. Use the
external installation options on your electrical distribution board or control cabinet to
connect the electrical installation correctly to ground / earth.
The DoP Converter DINrail has two screw terminals for mains power input (L / N) and
two terminals for mains power throughput (L / N).
Warning! As soon as you apply power to the DoP Converter DINrail
model’s mains power IN terminals, the mains power OUT (thru) terminals
become live. If you are not using the power OUT terminals, install a
connector on the terminals to make accidental contact with the terminals impossible.
Install the DoP Converter DINrail version inside a closed electric power
cabinet that is clearly marked with an electric shock hazard warning
notice similar to the one shown on the right.
DoP Converter UM
The DoP Converter UM has three screw terminals for mains power input (L / N / Ground)
and three terminals for mains power throughput (L / N / Ground). The voltage at the
throughput terminals is the same as that at the input terminals.
• The DoP Converter UM does not need to be connected to ground / earth but it has
ground / earth terminals that you can use to loop through the earth / ground
conductor when using three-conductor mains power cable. If you do not use the
DoP Converter UM’s ground /earth terminals, use the external installation options on
your electrical distribution board or control cabinet to connect the electrical
installation correctly to ground / earth.