GLP ArenaLED1 Touring handleiding
Handleiding
Je bekijkt pagina 18 van 33

www.glp.de GLP ArenaLED1 Touring
18 GLP ArenaLED1 Touring Safety and User Manual
Control data
Besides wireless setup using GLP iQ.Mesh via the GLP iQ.Service App, the fixture
can be controlled and set up using:
● USITT512 DMX over a standard DMX cable link
● RDM (Remote Device Management) over the DMX cable link.
See ‘Fixture overview’ on page 13. The fixture has 5-pin XLR IN (see B) and THRU (see
F) sockets for connection to a DMX cable link. Connectors use standard DMX pinout:
● Pin 1 = Ground
● Pin 2 = Negative / data cold
● Pin 3 = Positive / data hot
● Pins 4 and 5 are not used.
To link fixtures in cabled DMX daisy-chains using their XLR connectors, use certified
DMX cable with IP65-rated Neutrik TOP-compatible connectors only.
Remove the rubber seals from sockets before inserting cable connectors. Reinstall
the seal if you remove a cable connector from a socket. Keep rubber seals installed
on all unused sockets at all times.
If you would like advice about planning and installing a suitable control link, your
GLP supplier will be happy to provide assistance.