Recommended Maintenance
PART REQUIRED ACTION FREQUENCY
Pump Check oil level on pump. If oil level is
low, apply pump oil to pump.
Every Month
Check to make sure oil is clear. If oil
begins to look “milky” the oil must be
changed.
When using the vacuum packaging
machine with our products, it is
necessary to check the oil monthly.
For standard use, the oil will likely
need changed Every 5,000 cycles or
4 months.
Pump cleaning. Push the ''PUMP
CYCLE'' button and lower the lid at
the same time. Pump Cleaning will
appear on display. When cleaning is
complete, ''OIL'' will no longer display
and the program number will appear.
When ''OIL'' appears on display.
Pump Heating (GVP20A Only) With vacuum packaging machine
lid open, press the button ''PUMP
CYCLE'' for 3 seconds and let the
pump work for 5 seconds. Press the
''PUMP CYCLE'' button to stop the
pump.
Run the pump, but not at full power,
for few seconds. Lower the lid until
the pump starts. Open the lid after 5
seconds. Repeat two or 3 times.
During winter time or cold weather,
it is recommended to pre-heat the
pump in the morning in order to
liquefy the oil before it circulates
throughout the vacuum packaging
machine.
Sealing Bar Clean the sealing bar with alcohol. Every day. Replace sealing bar every
200 working hours.
Silicon Bar Clean the silicon bar with alcohol. Every day. Replace silicon bar every
200 working hours.
Oil Filter Replace the oil lter. Every year.