Operating Instructions
Note: If no other options are available, display will return to the
program number modied.
14. Connect the hose from the gas cylinder to the nozzle in the vacuum chamber.
15. Select the SET button. Display will show current gas setting (Figure 14-2).
Do not set time of gas ush longer than vacuum time.
The lid will open, anticipating the end of the cycle.
Make sure the gas pressure entering the chamber is not
higher than 1-1.5 bar.
16. Select the “up” or “down” arrow buttons to increase or decrease the time of
the gas injection (tenths of seconds, between 0 and 9.9 seconds).
17. Select the SET button to conrm the setting or select the next option.
VACUUM PACKAGING MACHINE OPERATION MODEL GVP20A
Do not operate vacuum packaging machine without
rst checking/installing oil into the motor/pump.
Damage to vacuum packaging machine will occur.
1. Place one or two of the ller plates in the vacuum packaging machine in order
to level the product with the height of the sealing bar (Figure 14-3).
Note: Filler plates can be used to reduce the required vacuum time.
Filler plates take up space, leaving less air to be removed from
the vacuum chamber.
2. Place the vacuum sealing bag (or bags) with the product, inside the vacuum
chamber.
3. Position the vacuum sealing bag with the opening at on the sealing bar
(Figure 14-4).
Note: Any excess top portion of the vacuum sealing bag should be
placed between the vacuum chamber wall and the sealing bar.
Excess top portion should not exceed 2 cm over the vacuum
sealing bag.
Note: Make sure to place any vacuum sealing bag that contains liquids
or wet product below the height of the seal bar.
4. Turn on the ON/OFF switch to power on the vacuum packaging machine. The
ON/OFF switch light will illuminate (Figure 14-5).
5. Refer to Program Settings in order to select the correct settings for the
vacuum chamber.
6. Once settings have been selected, lower the lid to start the vacuum cycle.
When lid if fully closed the vacuum cycle will begin.
7. If at anytime during the vacuum cycle the vacuum cycle needs to be stopped,
select and hold the ON/OFF display button for 3 seconds (Figure 14-6).
Note: The vacuum packaging machine will allow the air to enter the
vacuum chamber and the lid will open.
Note: To stop the vacuum cycle and seal the vacuum sealing bag,
select and hold the PUMP CYCLE button for 2-3 seconds.
8. Once the vacuum cycle is complete, the lid will automatically open.