18
Installation
GGF Series Gas Fryer
4. After ignition, the surface of the heat exchanger should become hot & dry quickly (within approximately 15
seconds). Noticeable heat should be felt rising from the pot, indicating acceptable operation.
5. If burners do not light after two (2) attempts, or appear not to be heating properly, refer to Section 7,
Troubleshooting.
6. If the burner system appears to be operational, return SELECTOR switch to [OFF] & proceed with the next test in
Section 2.12.3
.
2.12.2 Burner Test − continued
2.12.3 Filter Pump Test
1. Place the POWER switch ① in the [ON] position.
2. Open cabinet door.
3. With the filter pan disconnected, place the palm
of the hand tightly over the filter pan hose quick‐
coupling ② opening.
4. Briefly place the SELECTOR switch ③ in the
[FILTER PUMP] position, then return to the
centered [OFF] position. If suction is felt, when
the pump ran, it is operating correctly; continue
to Section 2.12.4.
If the pump does not run, no suction is felt, or air
is blowing outward, refer to the Section 7,
Troubleshooting.
The following test will verify that the Filter Pump is operating correctly.
3