2 31-5000842 Rev. 1
SPECIFICATIONS
MERCURY NOTICE: This product does not contain mercury.
However, this product may replace a product that contains
mercury. Mercury and products containing mercury must not be
discarded in household trash. Refer to thermostat-recycle.org
for information on disposing of products containing mercury.
Electrical Rating:
Input-Hardwire 24 VAC (18-30 VAC)
Load -1 amp maximum per output
-4 amp maximum total load
Setpoint Range 60° to 85° F (16° to 29° C)
Operating Ambient 40º F to 99º F (4º C to 37º C)
Occupancy Sensor Range 5 meters, 109.6 degrees x 109.6 degrees
Field of View
O1/O2 Dry Contact Ratings .5A @ 32VAC or .5A @ 30VDC
Humidity Range/Accuracy 0 to 95% operating humidity range, +/- 5%
accuracy
Shipping Temperature
Range
-30°F to + 150°F (-34° to +65°C)
Thermostat Dimensions 3.9” H x 5.4” W x 1.03”
Thermostat Applications Maximum Stages Heat/ Cool
Single Stage Cooling, One or Two
Stage Heating
NOTE: Two stage heating = 1st
stage heat pump and 2nd stage
resistance heat
3/2
Two Stage Cooling, Three Stage
Heating
NOTE: Three stage heating = 2
stage heat pump and 3rd stage
resistance heat
2-Way Communication with select
GE Appliance products