22 1557900 REV B 1 Garrett Metal Detectors
9. Return to the base sensitivity menu item and
enter the alarm level reading that you chose in
Step 7 as the base sensitivity.
10. Conrm new base sensitivity setting is appropri-
ate by testing the selected test object at varying
locations and orientations within the walk-
through (alarms should occur with each pass),
particularly in critical locations and orienta-
tions where you suspect detection is the most
dicult.
11. After setting the base sensitivity, verify detec-
tion in all zones. If alarms do not occur in
the critical locations, preferably increase the
zone boost for that location, or increase base
sensitivity.
Using Alarm Level to evaluate interference:
1. View for several seconds. A reading greater than
190 is ideal. Otherwise, interference is present.
2. Ensure the detector is not moving and there is
no movement of nearby metal or people.
3. Gently press the + (plus) keypad to reset the
Alarm Level reading.
4. Observe the Alarm Level reading for several
seconds.
5. Repeat steps 3 and 4 several times to determine
the background interference Alarm Level
number.
6. It is desired that the Alarm Level numbers
remain very close to or greater than 200, indicat-
ing small levels of interference.
7. If necessary, try switching o nearby equipment
or moving the detector and repeating steps 2,
3, 4, and 5 in order to determine the source and/or
location of interference.
8. To view the interference using zone lights,
turn Motion Sensor O and increase
Base Sensitivity to a value higher than the
background interference Alarm Level number.
Zone Sensitivity Boost
Individually adjusting Boost in the detectors separate
zones can help ensure uniform detection by compen-
sating for external stationary metal, if needed, such
as excessive metal in the oor; or it can be used to
increase or decrease detection in certain areas, if de-
sired, such as reducing shoe alarms at the oor.
e Paragon contains a total of 66 zones: 22 zones
from top to bottom and three zones from left to
right. However, for the sake of simplicity in making
individual zone adjustments, these 66 zones are con-
solidated into 22 adjustable areas from top to bot-
tom. ese 22 adjustable areas are displayed on the
walk-throughs LCD as Zones 1–22. e 22 zones
and their corresponding zone lights are shown in Fig-
ure 5-3 on the next page.
Zone Boost applies a percentage of gain, or attenu-
ation, to objects passing through that zone. For ex-
ample, setting Boost to +10% will make the response
of objects in that zone 10% stronger. Likewise, set-
ting Boost to -10% will make the response of objects
in that zone 10% weaker. Leaving Boost set to +0%
means no additional gain or attenuation is applied to
objects in that zone.
e user may increase or decrease the percentage of
Zone Boost in 1% increments by pressing the + (to
increase) or - (to decrease) keypads.
e adjustment ranges for the zones are as follows:
1. ZONE 1: -50% to + 50%
2. ZONE 2: -50% to + 50%
3. ZONE 3: -15% to + 15%
4. ZONE 4: -15% to + 15%
5. ZONE 5: -15% to + 15%
6. ZONE 6: -15% to + 15%
7. ZONE 7: -15% to + 15%
8. ZONE 8: -15% to + 15%
9. ZONE 9: -15% to + 15%
10. ZONE 10: -15% to + 15%
11. ZONE 11: -15% to + 15%
12. ZONE 12: -15% to + 15%
13. ZONE 13: -15% to + 15%
14. ZONE 14: -15% to + 15%
15. ZONE 15: -15% to + 15%
16. ZONE 16: -15% to + 15%
17. ZONE 17: -15% to + 15%
18. ZONE 18: -15% to + 15%
19. ZONE 19: -100% to + 150%
20. ZONE 20: -100% to + 150%
21. ZONE 21: -100% to + 150%
22. ZONE 22: -100% to + 150%