1557900 REV B1 Paragon User Manual 13
5. Determine the location of the AC power outlet
and select a power connection means. If power is
to be supplied from an overhead source, remove
the rubber access plug in the top of the detection
unit, feed the power cord (or the 2’ AC jumper
cord if required) into the detection unit and plug
directly into the power module.
If power is to be supplied at oor level, deter-
mine the panel that is nearest the power out-
let. Within the detection unit, plug in the 2’
AC jumper cord from the selected panel to the
power module. Retrieve the power cable at the
bottom of the entrance side of the selected panel
through the opening in the bottom of the panel.
(See Figure 3–7.)
Slip the power cord into the clamp to prevent
pinching and abrasion when the unit is set up-
right. Secure the connection with electrical tape
or other means if required.
6. Use the four remaining screws and washers to
attach the beacon crosspiece to the two panels.
(See Figure 3–8.)
7. Open beacon crosspiece and insert 15-pin cable
into Panel A. Ensure connector is facing the cor-
rect way. Do not force connection as bent pins
could ruin the panel.
8. If optional adhesive oor mounts are to be
used, attach the mounting plates to side panels.
Do not remove adhesive protectors at this
time. Follow instructions provided in the
mounting kit.
9. Use two or more people to lift Paragon to a
vertical position and move to desired location.
(See Figure 3–9.)
10. Ensure Paragon is physically stable and does not
sit on top of power cord.
11. Orient Paragon for operation where the beacon
crosspiece is the entrance side and the detection
unit is the exit side.
12. Tighten all screws.
Power Cord Wiring Description
Paragon includes a standard American ground
power cord. To replace or remove plug use:
Green To Ground
Black To line Hot
White To line Neutral
Paragon INTERNATIONAL includes a Euro-
pean power cord. To replace or remove plug use:
Green/Yellow To Ground
Brown To line Hot
Blue To line Neutral
FLOOR
Styrofoam
Packing Insert
DETECTION UNIT
CROSSPIECE
Installation
FIGURE 3-8
FIGURE 3-8: Power cable retrieval
FIGURE 3-9
Note: Do not replace detachable mains supply cords
with inadequately rated cords.
PANEL B
ENTRANCE
EXIT
PANEL A
BEACON CROSSPIECE
DETECTION UNIT