2. MAINTENANCE
2-6
2. There is a groove alongside the cover that has to be aligned and fit around the
tongue on the bracket. Align the tongue on the bracket and groove alongside the
cover.
3. Attach the cap to the hole at the top of the cover, then insert the safety clip.
Note: Make sure the safety clip is mounted correctly, referring to the following fig-
ure.
2.2.3 Normal self test
The normal self test transmits a test signal on all frequencies (121.5 MHz, AIS (VR-
7024F only) and 406 MHz), to check that the main functionality of the EPIRB works
properly. These test signals are not recognized as distress signals. While transmitting
the test signals, the battery and the transmitted signals are tested.
Note: Hold the capsule by its handle during the test. This keeps foreign material away
from the silicone grease on the capsule, and keeps the antenna of the capsule away
from metallic objects or human body.
Align this groove to the
tongue on the bracket.
Align this groove to the
tongue on the bracket.
Cap
Safety clipSafety clip