2. MAINTENANCE
2-4
Do not use force to reattach the capsule and bracket cover. Also, confirm that there
is no space or foreign material between the storage module and docking module
(see figure below). If the capsule is not seated in the bracket correctly, the commu-
nication error occurs on the remote alarm panel after 10 minutes and the capsule
may transmit the signal because that the electrodes are shorted by water.
Confirm that the error related to the Float-free DRU does not occur after the main-
tenance.
The strobe light flashes at three second intervals when the capsule is transmitting
the signal. If, during maintenance, the signal is accidentally transmitted, dry the
electrodes of the capsule with a towel, then return it to the bracket. If the signal is
still being transmitted, take the capsule to a steel cabin. Then, inform the search and
rescue authorities of the accidental transmission.
Note: The Float-free DRU does not have a power switch. If the strobe light contin-
ues flashing in spite of the above measures, remove the internal battery from the
capsule.
2.2.2 Monthly maintenance
Check the following points in the monthly maintenance.
Maintenance point Result
Around the bracket
Confirm that there is no object or structure which can interrupt the release of
the capsule.
Confirm that the cable connected to the bracket is fixed correctly.
Confirm that the bracket is fixed to the mounting location and fixing bolts are
fastened firmly.
Appearance of the bracket
Confirm that the bracket is not damaged and the characters inscribed on the
bracket are readable.
Confirm that no paint is applied to the bracket.
Inside the bracket
Confirm that water has not entered into the bracket.
Confirm that there is no damage to the capsule, and all external parts (stickers,
etc.) are in place.
The expiration date for the battery and hydrostatic release unit is as follows:
Battery: Five years (from date of coding or replacement)
Hydrostatic release unit: Two years (from date of coding or replacement)
The expiration date is indicated on the sticker attached to the capsule and hy-
drostatic release unit. Confirm that the expiration date has not passed.
OK
The notch on the
docking module is
placed in the groove
of the storage module.
No space or foreign
material between the
storage module and
docking module.
WRONG
The notch on the
docking module is
not placed in the
groove of the
storage module.
There is space
between the
storage module and
docking module.