SP - 1 E7255S01B
SPECIFICATIONS OF INTEGRATED HEADING SENSOR
PG-500
1 GENERAL
1.1 Heading Accuracy 1.0°rms (horizontal)
1.5°rms (within 30°)
1.2 Display resolution 0.1°
1.3 Follow-up 30°/s rate-of turn
1.4 I/O Port Input: 1 port
Output: 2 ports (one port drives 3 outputs)
1.5 Interface
Output FURUNO AD-10 format
IEC 61162-1 (NMEA 0183 Ver2.0)
HDG, HDT, HDM
Input IEC 61162-1 (NMEA 0183 Ver1.5/2.0)
RMC, VTG
1.6 Data Update AD-10 formatted: 25 ms
IEC 61162-1 (NMEA 0183): 100ms, 200 ms or 1 s selected
2 POWER SUPPLY
12-24 VDC: 0.12-0.03 A
3 ENVIRONMENTAL CONDITION
3.1 Ambient Temperature -15°C to +55°C
3.2 Relative Humidity 95% at 40°C
3.3 Waterproof IP5 (IEC 60529), CFR-46 (USCG standard)
3.4 Vibration IEC 60945
4 COLOR
N3.0