Furuno PG-500 handleiding

32 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 18 van 32
3. INSTALLATION
11
3.4 Heading Alignment
Heading alignment is required when sensor
heading is different from actual heading.
This alignment must be done using magnetic
heading (default setting).
CAUTION
Turn off the autopilot before aligning
heading.
The autopilot may turn the rudder suddenly.
Procedure
1. Press the [ADJ] key more than two
seconds. All LEDs go off.
AUTO
TRUE CALB STATUS
: Off
Note: Complete the next step within 10
seconds, otherwise normal operation
is restored.
2. Set difference between sensor heading
(output) and actual heading with the
[DAMP] key for “+” or [ADJ] key for “-”.
For example, the heading output by the
sensor is 70° and the actual heading is
75°. Therefore, the difference is +5°.
Press the [DAMP] key five times to set
+5°. Each time the [DAMP] key is
pressed, the LEDs light as shown below.
AUTO
TRUE CALB
STATUS
: On
: Off
+1°
+2°
+3°
+4°
+5°
+6°
+7°
Repeat
LED state and pressing of [DAMP] key
When pressing the [ADJ] key, the above
sequence begins from the STATUS LED
side.