2. WIRING
2-5
2.3 External KP Cable
The Connector Kit for TX Sync (see the table below) and the cable MPYC(SLA)-4 are
required to connect external KP.
Contents of Connector kit for TX sync
Note: FURUNO recommends use of the JIS cable MPYC(SLA)-4 (or equivalent, see
Appendix 1). However, if the wiring environment is such that the cable may contact
seawater, use a cable whose armor is covered with a vinyl sheath to prevent corro-
sion.
1. Fabricate the cable for the external KP as shown below.
a) Make the length of the wires of the PH connector assembly (supplied) 100 mm.
b) Remove the sheath from the cores 10 mm.
c) Fold back the cores in half. Attach crimp-on lug NCW-1.25 (supplied) to each
core.
d) Remove the armor 300 mm and cut off the vinyl sheath 130 mm
Name Type Code No. Qty Remarks
Upset UI Screw-B M4×20 000-163-756-10 2
Super Gland MGB20M-12B 000-177-248-10 1
PH Connector Assembly 02-1097 (4P) 001-206-000 1
Cable Clamping Plate 02-167-1528 100-379-090-10 1
Rainproof Panel 02-167-1529 100-379-100-10 1 No use. May be
discarded.
EMI Core GRFC-10 000-177-010-10 1
Crimp-on Lug NCW-1.25 000-157-213-10 4
(b)
Approx. 10 mm
(a)
Approx. 100 mm
(c)
Fold back core.
A
rmor
300 mm
Vinyl sheath
130 mm
80 mm
Shield
MPYC(SLA)-4