2-1
2. WIRING
Connect the power cable and transducer cable as shown below. See the next page
for how to fabricate the transducer cable.
2.1 Ground
Connect a ground wire (IV-2 sq, local supply) between the ground terminal and ship’s
ground to prevent interference to the sounder picture. Make the length of the wire as
short as possible. For FRP vessels, install a ground plate (approx. 20 cm by 30 cm)
on the outside of the hull bottom and connect the ground wire there.
Ground wire
(IV-2 sq)
MOD-Z072-050+, 5 m
(option: 2/10 m)
TZT9/TZT14/TZTBB
TZTL12F/TZTL15F/TZT2BB
TZT12F/TZT16F/TZT19F
GROUND
MJ-A3SPF0013-035C
(3.5 m)
External
KP
Transducer
B54, SS54, or TM54
Power supply
(12-24 VDC)
1.4-0.7A