Furman SmartSequencer CN-1800S handleiding
Handleiding
Je bekijkt pagina 3 van 16

2
Table of Contents
Feature Descriptions_____________________________________________________________________________________________2 & 3
Important Safety Instructions__________________________________________________________________________________________ 3
Quick Start Diagrams____________________________________________________________________________________________ 4 & 5
SmartSequencing™ 101 ____________________________________________________________________________________________ 6
Front Panel Overview _________________________________________________________________________________ 6, 7, 8, 9, 10 & 11
Rear Panel Overview___________________________________________________________________________________________ 12 & 13
Setup and Troubleshooting__________________________________________________________________________________________ 13
RS-232 Installation and Command Set_________________________________________________________________________________ 14
BlueBOLT™_________________________________________________________________________________________________14
Specifications ___________________________________________________________________________________________________ 14
FCC Notice and Customer Service_____________________________________________________________________________________ 14
15 Year Limited Warranty___________________________________________________________________________________________ 14
SmartSequencing™
Furman SmartSequencing™ is a contractor-friendly technology that
makes AC power sequencing easy to employ by non-technical person-
nel. Multiple Furman Contactor Series units can be linked together using
inexpensive two conductor wire, thus creating a vast control system.
Generally, high-priced automation systems are used for large, innovative
installs, yet these control systems seldom combine AC power distribu-
tion, filtering, and protection. Furthermore, many automation systems are
difficult to implement on smaller budgets. SmartSequencing™ provides
the answer right out of the box by offering a simple approach to AC power
management and control. Furman’s newest power sequencing technology
is an end-to-end solution that is operational up to 1000 feet via a non-
polarized, isolated current loop. In situations where power sequencing is
critical, or more than one AC electrical circuit is utilized, wiring Furman
SmartSequencing™ products in series is simple, fast and reliable.
SMP (Series Multi-Stage Protection)
Furman’s SMP surge suppression virtually eliminates service calls and
costly “down time”. Traditional surge suppression circuits sacrifice
themselves when exposed to multiple transient voltage spikes, requiring
your system to be dismantled and your surge suppresser to be repaired.
This does not happen with Furman’s SMP. Damaging transient voltages
are safely absorbed, clamped, and dissipated. Your connected equipment
is protected, while your Furman protects itself! Its unparalleled clamp-
ing voltage is unique to Furman’s SMP. According to UL 1449 Clamping
Level is defined as the amount of voltage that is allowed to pass through
to your equipment when the protection device is subjected to a transient
surge or spike. While other designs offer clamping voltages that clamp
well above 330 Vpk, Furman’s SMP clamps at 188 Vpk, (133 VAC RMS)
even when tested with multiple 6000 Vpk - 3000 Amp surges. This
unprecedented level of protection is only available with Furman’s SMP
technology!
EVS (EXTREME VOLTAGE SHUTDOWN)
Furman’s trusted (EVS) over-voltage circuitry protects against prolonged
over-voltage conditions, such as accidental connections to 208 or 240
VAC or an intermittent loss of neutral. It does so by monitoring the incom-
ing AC voltage. When an unsafe condition is detected, a relay shuts off
the incoming power until the overvoltage condition has been corrected.
The CN-1800S augments the EVS capability with Auto Reset options
allowing the end user to decide if the power should be reinstated, or re-
main off until conditions return to acceptable limits. The Extreme Voltage
Shutdown technology is a tremendous asset.
LIFT (LINEAR FILTERING TECHNOLOGY)
Unfortunately, traditional AC power conditioners have been designed
under unrealistic laboratory conditions. Professional audio/video compo-
nents are constantly bombarded by electromagnetic interference (EMI)
and radio frequency interference (RFI) via their AC power source. Prior
technologies, whether they were multiple-pole or conventional series-
mode filters, could actually harm audio and video performance more than
they help, due to the resonant peaking of their antiquated, non-linear de-
signs. Under certain conditions, these designs can actually add more than
10 dB of noise to the incoming AC line! Worse still, AC noise and ground
contamination frequently causes system reboots, sync issues and even
data loss. LiFT takes a different approach, ensuring optimal performance
through Furman’s linear AC noise filtering with no ground contamination.
Bekijk gratis de handleiding van Furman SmartSequencer CN-1800S, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Furman |
| Model | SmartSequencer CN-1800S |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 3240 MB |