CN-2400S Controls two ASD-120 2.0 Sequencers with an optional Fire Alarm Force OFF.
Diagram #5 illustrates a Furman CN-2400S Contractor Series controlling two
ASD-120 2.0 sequencers with a fire alarm providing an emergency FORCE OFF:
1. CN-2400 S DELAY 3 RELAY OUTPUT (NC) and (C) terminals connect appropriately to
both ASD-120 2.0 units per the 12V and REM terminals with a parallel connection.
• (NC) to both 12V and (C) to both REM.
2. Configure Multi-Function DIP on the CN-2400S, factory default with DIP 4 UP.
• DIP 4 UP – (NO), verify factory default.
◦ • CN-2400S DIP 2 is also set UP for a longer delay time.
3. Fire alarm contacts connected to FORCE OFF terminals on both ASD-120s
(parallel connection).
• Configure DIP 4 switch on ASD-120 2.0 to NO or NC depending on the contact type.
used at the fire alarm. Typically NC is the best terminal option for Event Production.
• Configure Multi-Function DIP on each ASD-120 2.0, factory default with DIP 4 UP.
All Delay Bank LED indicators will flash when FORCE OFF is activated.
• Optionally, the fire alarm contacts can also be connected to the FORCE OFF terminals of the
CN-2400 S if desired.
4. Configure ASD-120 2.0 Multi-Function DIP for Normally Closed & Maintained Mode ON.
• DIP 4 UP – (NO), verify factory default.
• DIP 7 DOWN – MNT, verify factory default.
ASD-120 2.0 DIP 1 is also set UP for a shorter delay time.
TWO ASD-120 2.0 UNITS CONTROLLED BY A CN-2400S AND BY FIRE ALARM
1 2 3 4 5 6 7
ON
1 2 3 4 5 6 7 8 9
ON
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7
ON
FORCE OFF
DELAY 3
NO
NC
C
FO
FO
CN-2400S DIP SETTINGS
CN-2400S DIP SETTINGS
ASD-120 2.0 DIP SETTINGS
ASD-120 2.0 DIP SETTINGS
FIRE ALARM
SYSTEM TRIGGER
+12V
STAT
REM
GND
REMOTE PORT
OPTIONAL
REMOTE
SWITCH
REMOTE
12V STAT REM GND
FORCE OFF
FORCE OFF
NO
C
NC
REMOTE
12V STAT REM GND
When the CN-2400S is sequenced ON, the CN-2400S unit’s DELAY 3 Contact Relay will trigger both
ASD-120 2.0 units to begin their respective programmed sequence.
Caution: The OFF sequence for the CN2400S and ASD-120 2.0 units will start at the same time.
In order to avoid timing conflicts while ramping down, the CN-2400S should be set to a longer delay time interval than all the time intervals on each ASD-120 2.0 sequencer.
ASD-120 2.0 ADVANCED INSTALLATION WITH FURMAN CN SERIES AND REMOTE RS-1 SWITCH
ON
ON
CN-2400S
DIP SETTINGS
ASD-120 2.0 DIP SETTINGS
FIRE ALARM
NO C NC
FORCE
REMOTE
12V STAT REM GND
12V STAT REM GND
DLY
ADJ
1 2 3 4 5 6 7
ALWAYS ON
ALWAYS OFF
S
E
Q
*SET TO MIDDLE POSITION
DELAY OUTPUTS
NC A B C D E F NO
12V
12V
REM
1 2 3 4 5 6 7 8 9
ON
CN-2400S
DIP SETTINGS
1 2 3 4 5 6 7 8 9
ON
CN-20MP
DIP SETTINGS
1 2 3 4 5 6 7 8 9
ON
CN-20MP
DIP SETTINGS
1 2 3 4 5 6 7 8 9
ON
CN-20MP
DIP SETTINGS
1 2 3 4 5 6 7 8 9
ON
CN-20MP
DIP SETTINGS
1 2 3 4 5 6 7 8 9
12V
12V
12V
12V
REM
REM
REM
REM
REM
Diagram Example #6
An ASD-120 2.0 Sequencer is controlled by a single RS-1 Remote System Control Panel and the
ASD-120 2.0 remotely activates Furman Contractor Series Products with Bank DELAY OUTPUTS A through F.
Diagram #6 illustrates a Furman ASD-120 2.0 sequencer controlling six Furman Contractor Series
units and a fire alarm provides an optional FORCE OFF:
1. Connect CN-2400S and CN-20MP REM terminal pins to ASD-120 2.0 DELAY OUTPUT (NC)..
2. Connect a 12V terminal pin from each CN-2400S and CN-20MP to an appropriate
A through F pin at the ASD-120 2.0 DELAY OUTPUT interface.
3. Configuration Multi-Function DIP on the CN-2400S units are factory default with DIP 4 UP.
• Only DIP 1 is set DOWN for a shorter than ASD-120 2.0 delay time on each CN-2400S unit.
4. Configuration Multi-Function DIP on the CN-20MP units are factory default with DIP 4 UP.
• Only DIP 1 is set DOWN for a shorter than ASD-120 2.0 delay time on each CN-20MP unit.
5. Optionally, a fire alarm can be connected to FORCE OFF
at the ASD-120 2.0, if desired.
• Configure Multi-Function DIP on the ASD-120 2.0, factory
default with DIP 4 UP.
All Delay Bank LED indicators will flash when FORCE OFF
is activated.
6. RS-1 terminals are connected to the ASD-120 2.0
REMOTE terminals, pole to pole:
• 12V to 12V, REM to REM, STAT to STAT, and GND to GND.
7. Configure ASD-120 2.0 Multi-Function DIP for
Normally Closed and Maintained Mode ON.
ASD-120 2.0 DIP 2 is set UP for a longer delay time than
Contractor Series units.
• DIP 4 UP – (NO), verify factory default.
• DIP 7 DOWN – MNT, verify factory default.
• Ensure all Bypass Set DIP switches are SEQ.
• Set ASD-120 2.0 Key Switch to Remote.
ON/OFF Sequences are triggered by the RS-1 Key Switch or by the rotating the Key Switch to ON at the ASD-120 2.0 as an RS-1 override.
DIAGRAM EXAMPLE 5
DIAGRAM EXAMPLE 6

Bekijk gratis de handleiding van Furman ASD-120 2.0, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkFurman
ModelASD-120 2.0
CategorieNiet gecategoriseerd
TaalNederlands
Grootte3501 MB