KNOW YOUR PRODUCTSET UP & PREPARATION
Before connecting the tool, check the air compressor gauge to be sure it is
functioning within the proper range 5 - 7 bar (72.5 - 101.5 psi).
Note: The tool and air hose must have a quick-connect hose coupling that allows
all pressure to be removed from the tool when the coupling is disconnected.
1. Pull back the sleeve on female quick connector hose coupling, insert male end
and release sleeve on quick connector.
Note: For best performance use 3/8” I/D supply air hose.
WARNING! Ensure the tool is in the off position before connecting to the
air supply.
WARNING! Ensure that the compressed air does not exceed 101.5 psi (7
bar) while operating the tool. Too high an air pressure and unclean air will
shorten the product’s life due to excessive wear, and may be dangerous
causing damage and/or personal injury.
WARNING! Always use a coupling that discharges all the compressed
air in the tool at the time the fitting or hose coupling is disconnected.
Using a coupling that does not discharge the compressed air could cause
unintended operation and serious personal injury..
Connecting air supply
1. Wrap Teflon tape (not supplied) around the Nitto Style Fitting approximately 4
to 5 times to ensure a leak free seal.
2. Screw in Nitto Style Fitting to the air inlet of the Air Hydraulic Riveter.
3. Fasten the Nitto Style Fitting using a 14mm spanner (not supplied).