DUCT PIECES
EQUIVALENT
LENGTH
x
NUMBER
USED
=
EQUIVALENT
LENGTH
Rectangular-to-Round
Transition Adaptor*
5 Ft. (1.5 m) x ( ) = Ft. or m
Wall Cap 40 Ft. (12.2 m) x ( ) = Ft. or m
90° Elbow 10 Ft. (3 m) x ( ) = Ft. or m
45° Elbow 5 Ft. (1.5 m) x ( ) = Ft. or m
90° Elbow 25 Ft. (7.6 m) x ( ) = Ft. or m
45° Elbow 5 Ft. (1.5 m) x ( ) = Ft. or m
Roof Cap 24 Ft. (7.3 m) x ( ) = Ft. or m
Straight Duct 6“ (15.2
cm) Round or 31⁄4“ x 10“
(8.2 x 25.4 cm
Rectangular)
1 Ft. (0.3 m) x ( ) = Ft. or m
Total Ductwork = Ft. or m
NOTE: If you need to install ducts, note that the
total duct length of 34" x 10" (8.2 x 25.4 cm)
rectangular or 5" (12.7 cm) diameter/ 6" (15.2
cm) diameter round duct should not exceed
140 equivalent feet (42.7 m).Outside ventilation
requires an EXTERNAL EXHAUST DUCT. Read
the following carefully. NOTE: It is important
that venting be installed using the most direct
route and with as few elbows as possible. This
ensures clear venting of exhaust and helps prevent
blockages. Also, make sure dampers swing freely
and nothing is blocking the ducts.
Exhaust connection:
The exhaust adaptor has been designed to
mate with a standard 34" x 10" (8.2 x 25.4 cm)
rectangular duct. If a round duct is required, a
rectangular-to-round transition adaptor must be
used. "A5 "(12.7cm)/ "6"(15.2cm) diameter duct is
acceptable to use.
Maximum duct length:
For satisfactory air movement, the total duct
length of 34" x 10" (8.2 x 25.4 cm) rectangular or
5" (12.7 cm) diameter/6" (15.2 cm) diameter round
duct should not exceed 140 equivalerfeet (42.7 m).
Elbows, transitions, wall and roof caps,
etc.,
present additional resistance to airflow and
are equivalent to a section of straight duct
which is longer than their actual physical size.
When calculating the total duct length, add the
equivalent lengths of all transitions and adaptors
plus the length of all straight duct sections.The
chart below shows you how to calculate total
equivalent ductwork length using the approximate
feet of equivalent length of some typical ducts.
* IMPORTANT: If a rectangular-to-
round transition adaptor is used,
the bottom corners of the damper
will have to be cut to fit, using the
tin snips, in order to allow free
movement of the damper.
Equivalent lengths of duct pieces are based on
actual tests and reflect requirements for good
venting performance with any vent hood.
EN-13
Installation Instructions
INSTALLATION INSTRUCTIONS FOR EXTERNAL EXHAUST DUCTING