EQU
IVALENT
NU
MBER
EQU
IVALENT
DUCT PIECES LENGTH x USED = LENGTH
Roof Cap 24 Ft. (7.3 m) x (1) = 24 Ft. (7.3 m)
12 Ft. (3.6 m) x (1) = 12 Ft. (3.6 m)
12 Ft. (3.6 m)
Straight Duct
(6"/15.2 cm Round)
5 Ft. (1.5 m) x (1) = 5 Ft. (1.5 m)
Rectangular-to-
Round Transition
Adaptor*
Equivalent lengths of duct pieces are based on
actual tests and reflect requirements for good
venting performance with any vent hood.
Total Length = 41 Ft. (12.5 m)
The
fo
llowing chart describes an example of one
possible ductwork installation.
OUTSIDE TOP EXHAUST (EXAMPLE
ONLY)
NOTE:
For back exhaust, care should be taken to align exhaust with space between studs, or wall
should be prepared at the time it is constructed by leaving enough space between the wall studs to
accommodate exhaust.
* IMPORTANT: If a rectangular-to-round transition adaptor is used, the bottom corners of the
damper will have to be cut to fit, using the tin snips, in order to allow free movement of the
damper.
The following chart describes an example of one
possible ductwork installation.
In
stallation Instructions
OUTSIDE BACK EXHAUST (EXAMPLE ONLY)
EQUIVALENT NU
MBER
EQU
IVALENT
DUCT PIECES LENGTH* x USED = LENGTH
Wall Cap 40 Ft. (12.2 m)x (1) = 40 Ft. (12.2 m)
3 Ft. (0.9 m) x (1) = 3 Ft. (0.9 m)
3 Ft. Straight Duct
(3
1
⁄4" x 10"/8.2 x
25.4 cm
Rectangular)
90° Elbow 10 Ft. (3 m) x (2) = 20 Ft. (3 m)
Equivalent lengths of duct pieces are based on
actual tests and reflect requirements for good
venting performance with any vent hood.
Total Length = 63 Ft. (19.2 m)
EXT
ERNA
L EXHAUST DUCTING
EN-15