UNIT DISASSEMBLY AND COMPONENT REPLACEMENT
Remove Chassis
The Front Panel needs to be removed prior to any repair or
troubleshooting procedures.
1. Front panel is removed by lifting up and rotating back and down.
2. Remove 4 mounting screws and slide unit out of sleeve.
Figure 701 (Chassis Removal)
CAUTION
Unit weighs approximately 120 pounds.
Use caution when removing to prevent
personal injury or damage to the equipment.
WARNING
ELECTRIC SHOCK HAZARD
Turn off electric power before service or
installation. Extreme care must be used, if it
becomes necessary to work on equipment with
power applied.
Failure to do so could result in serious injury or
death.