Friedrich ZoneAire Select PZH12K3SC handleiding
Handleiding
Je bekijkt pagina 24 van 73

24
PB
OPERATION
Function and Control
(After reprogramming, disconnect the power cord and then power up again to make it effective)
Warning: #2 and #3 should be matched the unit type, but #2 can be switched to OFF to set as Emergency Heat Override! This will
cause the E-heater to run all the time.
Advanced Settings
When unit is OFF, press the cool key and fan speed key at the same time for more than 5s. When d0 is displayed, it will enter the advanced
parameter setting state;
Press cool key to switch parameter code and parameter value;
Press + or -key to switch parameter code or set parameter value;
ON/OFF key is used to save and exit settings
Code Function description Parameter value Parameter value description
d0 Selection of temperature unit ˚F The unit of temperature is
Fahrenheit.
˚C The unit of temperature is Celsius.
d1 Select of control method P The control method is touchpad
control.
r The control method is universal
24V thermostat control.
d2 Maximum temperature setting d3 to /90˚F Setting the maximum value is d2,
default d2 is 90˚F
d3 Minimum temperature setting 60˚F ~~d2 Setting the minimum value is d3,
default d3 is 60˚F d2
d4 Indoor temperature calibration -9(~~9( Recalibration is required after
switching temperature unit
d5 Temperature display selection 0~~1 1 indicates the indoor sensor
temperature; 0 indicates the set
temperature
Table 207
Bekijk gratis de handleiding van Friedrich ZoneAire Select PZH12K3SC, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Friedrich |
| Model | ZoneAire Select PZH12K3SC |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 24942 MB |