SH20N50AT and SH24N30AT Adhere to the following certications:
CERTIFIED PER STD. NO. ANSI/ISA 12.12.01,2013
PER STD. NO. IEC 60079-0, 6th Edition PER STD. NO. IEC 60079-15, 4th Edition
PER STD. NO. CAN/CSA C22.2 NO. 213-M1987
PER STD. NO. CENELEC EN 60079-0: 2012 + A11: 2013
PER STD. NO. CENELEC EN 60079-15: 2010
CERTIFICATION DEMKO 15 ATEX 1364X II 3 G Ex ec nA nC IIC T4 Gc
IECEX UL15.0051X DEMKO 15 ATEX 1364X
SH20N50AT & SH24N30AT
Specic Conditions of Use:
Provision shall be made to prevent the rated voltage being exceeded by
the transient disturbances of more than 140% of the peak rated voltage.
The equipment must be installed only for use in locations providing
adequate protection against the entry of solid foreign objects or water
capable of impairing safety.
Only permanently wired cables may enter the cable glands. The user
shall provide for the required strain relief.
Degree of protection will be safeguarded only when sealing and cable
entry ttings are properly tted. To ensure proper protection, all wiring
connections and conduit passageways must have the appropriate ATEX/
IECEx certied plug or cable gland.
Cable Glands shall be mounted into the enclosure in such a way that
they are mechanically protected against impact force.
To avoid the buildup of electrostatic charge, regularly clean the unit with
a damp cloth.
The appliance is not to be used by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or instruction.
Children to be supervised not to play with the appliance.
The enclosure with a coating must not be used in areas affected by
charge-producing processes, mechanical friction and separation
process, electron emission (e.g. in the vicinity of electrostatic coating
equipment), and pneumatically conveyed dust.
Electrical Ratings:
Refrigerant System Ratings:
NOTICE: To maintain IP44 protection, the Hazardgard
unit must be installed in accordance to the installation
instructions stated in this document.
The following additional previous editions of Standards noted under the “Standards” section of this
Certicate where applied to integral Components as itemized below. There are no signicant safety re-
lated changes between these previous editions and the editions noted under the “Standards” section.
Junction Box, Part No. 25. 10 16
08, manufactured by Rose.
IEC 60079-7:2006-
07, IEC 60079-31:
ATEX & ICEX Standards Specic to Models SH20N50AT & SH24N30AT
ATEX/IECEx Model Number Rated Voltage,
Frequency
Rated Cooling
Amps
Compressor
RLA,LRA
Motor
FLA
Motor
HP
MCA MOP
SH20N50AT 240/220, 50Hz 11.6 9.4, 50 2 1/3 13.25 20
SH24N30AT 230/208, 60 Hz 11.8 10.2, 52 1.5 1/4 14.25 20
ATEX/IECEx Model Number R-410a Charge, oz High-Side Design Pressure (PSIG) Low-Side Design Pressure (PSIG)
SH20N50AT-B 40.7 600 300
SH24N30AT-A 46.8 600 300