Maintenance
8.2 Shut down the device
The device must be shut down before any maintenance work.
NOTICE
Function of the drying agent cartridges can fail
If the power supply is interrupted, the regeneration cycle is switched off. Compressed air flowing
through the adsorption dryer after the power supply has been switched off can permanently damage
the drying agent cartridges.
Ensure that compressed air is not fed to the dryer if the power feed is interrupted.
Fig. 14: Typical installation
1.
Close valve B.
2.
Close valve A.
3.
Run the dryer for 15 min to depressurise it completely.
4.
Switch off the power supply.
8.3
Remove covering and mount
The covering must be removed for maintenance work on the air gun nozzle and silencer. The covering
is fastened at the top with a spring insert and secured at the bottom with a screw. The PDAD-100 has
an additional screw in the upper part.
Removing covering
1.
Shut down the device
è
8.2 Shut down the device.
2.
Unscrew the bottom retaining screw.