Installation
Wiring diagram: DIO operation (digital I/O)
In NPN mode defined levels must be applied to the DI1/DI2 digital inputs of the EMCS, e.g.by
controller outputs with pull-up resistors (4.3kW recommended).
1
2
3
4
Fig. 4: Wiring diagram: DIO operation (digital I/O)
1
PELV fixed power supply for the load
voltage supply
2
PELV fixed power supply for the logic power
supply
3
Integrated drive EMCS-ST
4
Higher-order controller with digital I/O
Status and control signals
The following table shows the status and control signals and the electrical levels of the digital inputs
and outputs as a function of the "PNP/NPN" version of the integrated drive.
Status and control
signal
Electrical levels
PNP, positive logic NPN, negative logic
0 Low level (0V) High level (24V)
1 High level (24V) Low level (0V)
Tab. 2: Overview of status and control signals as a function of electrical levels
Wiring diagram: IO-Link operation
Current consumption of IO-Link power supply [Logic]
An input current at pin 1 (L+) of 100...150mA is required for operation.