Installation
7
• Take product weight into account
è
14 Technical data.
7 Mounting
WARNING
Risk of injury due to unexpected movement of components.
The drive can move freely in the voltage-free state. This can cause unexpected movements of the
connected mechanics and crush parts of the body.
• Bring moving parts of the mechanical system into a safe position.
• Mounting product è Operating instructions for electric cylinder EPCC-BS.
8 Installation
WARNING
Risk of injury due to electric shock.
• For the electrical power supply with extra-low voltages, use only PELV circuits that guarantee a
reinforced isolation from the mains network.
• Observe IEC60204-1/EN60204-1.
Damage to the device due to non-approved potentials at the pins
• Power connection:
• Do not connect pin3
• Logic connection:
•
Apply the logic supply [Logic Pin 1] and the IO-Link communication signal C/Q [Pin 3] at least
50 ms after the load supply 24 V DC [Power Pin 1]. For example, ensure the switch-on delay by
interposing relay contacts.
• Disconnect the logic supply [Logic Pin 1] and the IO-Link communication signal C/Q [Pin 3] after a
shutdown, after an interruption or before restoring the load supply 24 V DC [Power Pin 1].
• EMCS-ST is not hot-plug capable: 24V level to the digital outputs DO1/DO2 [Pin 2/3] or the
IO-Link communication signal C/Q [Pin 3] only after connecting the reference potentials GND/L–
[Pin 4/8].
• Disconnect the digital outputs DO1/DO2 [Pin 2/3] and the IO-Link communication signal C/Q
[Pin 3] at least 50 ms before the power supply connections GND/L– [Pin 4/8] and 24VDC/L+
Disconnect [Pin 1]. For example, ensure the switch-off delay by interposing relay contacts.
• GND and L– connections:
• Apply the Power, GND [Pin 2] and Logic, GND/L– [Pin 4/8] connections to one potential.
Forexample, ensure the same potential by using a common fixed power supply or an electrical
connection of the two 0 V DC GND potentials.
1.
Connect the power cable to the [Power] connection of the integrated drive EMCS-ST and to a PELV
fixed power supply.
2. Connect the logic cable to the [Logic] connection of the integrated drive EMCS-ST and to a
controller or to a IO-Link master.
Bekijk gratis de handleiding van Festo EPCS-BS-60-200-12P-A-ST-M-H1-PLK-AA, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Festo |
Model | EPCS-BS-60-200-12P-A-ST-M-H1-PLK-AA |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 2484 MB |