Operation
19
Homing after a restart as a function of the positioning task
Sequence
–
Mov
Ref
: force-controlled movement against mechanical stop "Mech
In
"
–
Mov
Out
: position-controlled movement to the reference end position"Ref"
–
Travel to the target position as a function of the positioning task
–
No travel, end position "Lim
In
" reached
–
Mov
Out
: position-controlled movement to the end position Lim
Out
–
Mov
Imp
: position-controlled travel to the intermediate position Lim
Imp
(IO-Link only)
Start
In
positioning task to the end position Lim
In
Start
Out
positioning task to the end position Lim
Out
Start
Imp
positioning task to the intermediate position Pos
Imp
(IO-Link only)
Tab. 10: Initialise restart sequence with reference end position "Ref"