Festo EPCE-TB-45-50-FL-MF-ST-M-H1-PLK-AA handleiding
Handleiding
Je bekijkt pagina 14 van 36

14
Festo — EPCE-TB — 2023-11d
Commissioning
1
3
4
5
2
Fig. 7: Wiring diagram: IO-Link operation via adapter NEFC
1
PELV fixed power supply for the load
voltage supply
2
PELV fixed power supply for the logic power
supply
3
Integrated drive EMCS-ST
4
IO-Link master with IO-Link interface
5
Adapter NEFC
Core colours of Festo cables:
BK=black, BN=brown, BU=blue, GN=green, GY=grey, PK=pink, WH=white, YE=yellow
9
Commissioning
WARNING
Risk of injury due to unexpected movement of components.
• Protect the positioning range from unwanted intervention.
• Keep foreign objects out of the positioning range.
• Perform commissioning with low dynamic response.
WARNING
Severe, irreversible injuries from accidental movements of the connected actuator technology.
Unintentional movements of the connected actuator technology can result from exchanging the con-
necting cables of a servo drive or between servo drives.
• Before commissioning: All cables must be correctly assigned and connected.