5. Serial Port Communication Control
In normal working state, you can control the camera through RS232/RS485 (VISCA IN)
cable. The parameter of RS232 is as below:
Baud rate: 2400/4800/9600/115200/second
Start Bit:1 bit;
Data Bit:8 bit;
Stop Bit:1 bit;
Verification Bit:None.
After power on, the camera will have a brief tour and then back to the center position.
The zoom lens is pulled to the farthest position, and then pulled back, after that
self-test is completed.
5.1 VISCA Protocol List
5.1.1 VISCA Protocol List
Ack/Completion Message
Command
Package
Remark
ACK
z0 41 FF
Returned when the command is accepted.
Completion
z0 51 FF
Returned when the command has been
executed.
z = Camera Address + 8
Error Messages
Command
Package
Remark