Handleiding
Je bekijkt pagina 20 van 34

- 20
-
MAINTENANCE
Shelf Light Bulb Replacement
1. All shelf light fixtures use a spring-loaded socket at one end. To remove the bulb push the bulb
towards the spring-loaded socket until the opposite ends drops out of the socket.
2. The bulb is inside a clear shatter proof tube with a black plastic cap on each end. Be careful not to
allow bulb to slide out of shatter proof tube.
3. Reinstall new bulb in to the existing shatter proof tube and reuse black plastic end caps. Reinstall
bulb assembly in the same manner as described in the Bulb Removal Procedure. Be sure bulb is
secure in bulb receptacles
Note: Be sure to use a direct equivalent to the original bulb.
PERIODIC MAINTENANCE
NOTICE:
Condenser coil must be cleaned a minimum of twice per month to insure
proper refrigeration performance and prevent compressor failure.
Failure to clean condenser coil will void condenser warranty.
Cleaning Condenser Coil (All Self Contained Refrigerated Units)
It is very important that the Condenser coil is cleaned twice per month to insure proper refrigeration
performance and to prevent compressor failure. Failure to clean condenser coil will void condenser
warranty.
1. Disconnect power to the unit.
2. Remove the back base panel located on the back bottom of unit by removing the (6) front panel
retaining screws.
3. Carefully vacuum the front surface of condenser coil. Take care not to bend coil fins with vacuum
cleaner nozzle.
4. Reinstall back panel and retaining screws.
VACUUM FRONT
SURFACE OF
CONDENSER COIL
(6) REAR BASE
PANEL SCREWS
Bekijk gratis de handleiding van Federal SSRPF5952, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.