REFRIGERATION
Self-Contained Models
MODEL
R134A
CHARGE
PRE 12
/1/19
R513A
CHARGE
POST
12
/1/19
REFRIGERATION
ITR3626 & ITR3634
& ITRSS
3626 & ITR
SS
3634
18 OZ
17 OZ
1/2HP
ITR4826 & ITR4834 & ITRSS4826 & ITRSS4834
20 OZ 19 OZ 1/2HP
ITR6026 & ITR6034
&
ITR
SS
6026 & ITR
SS
6034
24 OZ
23 OZ
1/2HP
The self-contained models manufactured before 12/1/19 are shipped from the factory with a completely
operational 134A refrigeration system and require no modifications or adjustments upon installation.
Models produced after 12/1/19 are shipped with 531A. Case must be installed per the installation section of
this manual to provide proper condensing air cooling.
Self-Contained Refrigeration Operation
The unit temperature is controlled by an electronic control that senses air temperature and turns
refrigeration on and off as required to maintain proper temperature.
The electronic control will also sense a frosted coil that requires a defrost cycle and shuts off refrigeration
until defrost is complete. There are also a defined number of scheduled defrosts that also shut the
refrigeration off to insure a full defrost.
Remote Models Use pressure gauges to set pressure control
MODEL
REFRIGERANT
PRE 12/1/19
REFRIGERANT
POST 12/1/19
REFRIGERATION
PRESSURE
CUT IN
PRESSURE
CUT 0UT
ITR3626R & ITR3634R &
ITRSS3626R & ITRSS3634R R134A R531A 3400 BTUH@90F/20F
25# 5 #
ITR4826R & ITR4834R &
ITRSS4826R & ITRSS4834R R134A R531A 3800 BTUH@90F/20F
25# 5 #
ITR6026R & ITR6034R &
ITRSS6026R & ITRSS6034R R134A R531A 4200 BTUH@90F/20F
25# 5 #
Use pressure gauges to set pressure control
Remote Refrigeration Operation
The remote models manufactured before 12/1/19 are designed to use 134A refrigerant and after 12/1/19 are
designed to use R531a refrigerant and shipped from the factory with the evaporator coil, expansion valve,
drier filter, sight glass and refrigerant solenoid valve. The required high-low-pressure control and remote
condenser can be provided as a factory option and will be required to be charged with 134a or R531A
refrigerant after installation.
The unit temperature is controlled by an electronic control that senses air temperature and opens and closes
the refrigerant solenoid valve as required to maintain proper temperature.