f. Position the C-ring assembly on the two V-rails so that the C-ring is centered over
the hole, as shown below.
g. Secure the C-ring to the V-rails using two screws.
V
-rail
C-ring
Figure 3. Positioning the C-ring Assembly on the V-rails
5. Route the speaker wires through the ceiling tile hole.
6. Configure the locking arms for thicker ceilings (optional).
Three speaker locking arms are used to secure the speaker to ceiling tiles up to
2.25 inches (57.1 mm) thick. The locking arms are equipped with removable inserts that
accommodate ceiling tiles of up to 1.5 inches (38.1 mm) in thickness. For ceiling tiles
thicker than 1.5 inches, the locking arm inserts must be removed.
To remove the inserts:
Using a screwdriver, rotate the locking arm so that the insert can be accessed.
Figure 4. Accessing the Locking Arm Insert
3
4
SF 3C LP and SF 3CT LP User Guide • Installation 6