Extron IPL EXP S2 handleiding
Handleiding
Je bekijkt pagina 32 van 49

IPL EXP I/O Series • Hardware Features and Installation 24
Digital output — To activate LEDs, incandescent lights, or other devices that accept a TTL signal, or to provide
contact closure control for projector lifts, motorized screens, room or light switches via an Extron IPA T RLY4 or
similar device, you can use one or more of these ports as a digital output. When a port is congured for digital
output, it oers two output states: on and o.
• When the port is set to an “on” state, (the switch 1 circuit is closed), the I/O pin is connected to ground. Output
voltage is less than 0.5 volts.
• When the port is set to the “off” state (the switch 1 circuit is open), the output pin floats (is not connected).
• If the application calls for TTL compatibility, the digital output circuit can be set up to provide a 2k ohm pull-up
resistor to +5 VDC, which you can use if the connected device does not provide its own power.
• If the pull-up resistor is disabled, voltage output is determined by an external source device.
• If the pull-up resistor is enabled, switch 2 is closed, voltage output is 4.3 VDC.
Each I/O port is capable of accepting 250 mA, maximum.
Bekijk gratis de handleiding van Extron IPL EXP S2, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Extron |
Model | IPL EXP S2 |
Categorie | Niet gecategoriseerd |
Taal | Nederlands |
Grootte | 7534 MB |