Extron FOX3 SR 301 handleiding

58 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 36 van 58
FOX3SR 301 and FOX3SR311 Scaling Receivers • SIS Configuration and Control 28
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Information requests (continued)
Information request
Verbose mode 2/3:
I SFPALnk
X2*
SFPBLnk
X2*
SigI
X$
HdcpI
X^
HdcpO
X&
AudI
X*
X(
X2(]
Inf00*SFPALnk
X2*
SFPBLnk
X2*
SigI
X$
HdcpI
X^
HdcpO
X&
AudI
X*
X(
X2(]
Response description:
Fiber link A•Fiber link B•Signal input•Input HDCP•Output HDCP•Input audio•Receiver•Fiber mode
]
Example:
I
SFPALnk1
SFPBLnk1
SigI1
HdcpI1
HdcpO1
AudI1
RX
SM
]
Signals are detected on the two fiber links, a signal is detected on the
input, the input and output are HDCP devices, the digital audio input is
selected, the device is a receiver, and the fiber mode is singlemode.
KEY:
X$
= Input video signal status 0 = Not detected 1 = Detected
X^
= Input HDCP status 0 = No source detected 1 = Source with HDCP detected (default)
2 = Source with no HDCP present
X&
= Output HDCP status 0 = No active sink detected 1 = Sink detected, output signal encrypted
2 = Sink detected, output signal not encrypted
X*
= Input audio selection 0 = Auto 1 = Digital 2 = Analog
X(
= Device type TX or RX
X2*
= Fiber link detection 0 = Not detected 1 = Detected
X2(
= Fiber optic mode SM or MM
DHCP client
Set DHCP on or off
E X1)
DH
}
Idh
X1)]
View DHCP status
E
DH
} X1)]
KEY:
X1)
= Set DHCP 0 = Off (default) 1 = On
Telnet port
Set Telnet port map
E
Z
X3%
PMAP
}
PmapZ
X3^]
Set Telnet port to
X3%.
View Telnet port map
E
ZPMAP
} X3^]
KEY:
X3%
= Enable Telnet port 23 0 = Off (default) 23 = Telnet port 23 enabled
X3^
= Port number Response is 5 digits with leading zeros, for example 00000 or 00023
Echo for SIS over SSH (port 22023)
Enable Echo
E
1ECHO
}
Echo1
]
Returns command entered with
response.
Disable Echo
E
0ECHO
}
Echo0
]
Returns response only.
View Echo status
E
ECHO
} X3)]
NOTE: The echo setting is for the current connection only, and remains until the connection is closed. Apply after connection is established.
KEY:
X3)
= Enable or disable 0 = Disable 1 = Enable (default)
Verbose mode
Set verbose mode
E X1&
CV
}
Vrb
X1&]
View verbose mode
E
CV
} X1&]
NOTE: Verbose mode will revert back to default in the event of a power cycle, disconnect from dataviewer, or disconnect from the Ethernet.
KEY:
X1&
= Verbose mode 0 = Clear/none (default for Ethernet) 1 = Verbose mode (default for RS-232)
2 = Tagged response for queries 3 = Verbose mode and tagged responses for queries
Timeout Ethernet data port
Set current port timeout
E
0*
X3!
TC
}
Pti0*
X3!]
View current port timeout
E
0TC
} X3!]
KEY:
X3!
= Timeout The number of seconds before timeout on IP connections (min=1, max=65000, with each number equivalent
to 10 seconds [default=30=300 seconds])