Configuration
This section of the user guide provides information about:
RS-232 Ports
RS-232 Control of Tx and Rx Units
SIS Commands
Command and Response Table for SIS Commands
FOX Extender Control Program
RS-232 Ports
Both the FOX Tx AV and FOX Rx AV have a front panel TRS port and a rear panel captive screw
port, which can provide SIS commands to configure the transmitter/receiver settings when
connected to a control device (see Command and Response Table for SIS Commands on
page 16).
NOTE: The two comm ports work in parallel. However, depending on the computer or the
communication settings, connecting to both comm ports at once may result in one or
both ports not working. Extron recommends that only one comm port (front or back) is
used at a time.
The protocol for both ports is 9600 baud, no parity, 8 data bits, 1 stop bit, and no flow control.
NOTE: Both RS-232 Remote and RS-232 Over Fiber signals require fiber optic link 1 and
link 2 for full functionality (see RS-232 Control of Tx and Rx Units on page 13).
The front panel Config port uses a 2.5 mm mini jack connector. Extron recommends the 9-pin D
Female to 2.5 mm TRS Configuration Cable (see www.extron.com).
Sleeve
(Gnd)
Ring
Tip
2.5 mm TRS connector
Pin TRS
Tip
Ring
Sleeve
Function
Transmit data
Receive data
Signal ground
T
x
R
x
Gnd
Figure 7. Front Panel RS-232 Port
NOTE: Control signal ground pins for Extron products may be labeled as or G. The wiring
and function are the same, whichever way your product is labeled.