EWT SNOWAIR12CP handleiding

72 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 31 van 72
NLFR EN
31
product whether it is working or
IMPORTANT: Do not use this unit
where the ambient temperature
is lower than 5°C, otherwise the
evaporating coil will ice up heav-
ily and this will affect the perfor-
mance of the product and poten-
NEVER drop or insert any object
Do not use the appliance in loca-
tions where paint, petrol or oth-
used or
Do not use bug sprays or oth-
cleansers/vapour
Always switch off the unit and
take the plug out of the socket.
Before you clean or carry out
In the event of an electrical storm.
WARNING - Keep batteries out of
reach of children, dispose of used
batteries immediately and safely.
WARNING - The remote control for
this unit contains a small battery.
To avoid risk of choking, keep the
remote away from children and do
not swallow the battery. If the bat-
tery is swallowed seek medical
Model SNOWAIR7C SNOWAIR9C/9CP SNOWAIR12C/12CP
Electrical Supply 220-240V~ – 50Hz 220-240V~ – 50Hz 220-240V~ – 50Hz
Refrigeration Power 7000 Btu/h 9000 Btu/h 12000 Btu/h
Cooling Current 3.4A 4.35A 5.3A
Rated Current 4.6A 5.21A 7A
EER 2.6 2.6 2.6
DehumidicationCapacity 14,5L/day 28L/day 36L/day
Cooling Input Power 790W 1000W 1230W
Rated Power 1050W 1200W 1350W
Refrigeration Power 2050W 2500W 3200W
Water Protection IPX0 IPX0 IPX0
Dimensions(LxWxH) L42xW31xH70 L42xW31xH70 L44xW35,5xH71,5
Net Weight 27kg 29kg 31kg
Refrigerant/Load/GPW R290 / 0.215kg / 3 R290 / 0.205kg / 3 R290 / 0.260kg / 3
CO2 Equivalent 0.006 tonnes 0.006 tonnes 0.006 tonnes
Containsuorinatedgreenhousegases Yes
Hermetically sealed system Yes
Air Conditioning Class Class A Class A Class A
MaxVentilatorFlow(F) 300m
3
/h 290m
3
/h 300m
3
/h
Sound Power Level (LWA) < 65 dB < 65 dB < 65 dB
Suction Pressure 1.2MPa 1.2MPa 1.2MPa
Charge Pressure 2.3MPA 2.3MPA 2.3MPA
Max.AllowablePressure 5MPa 5MPa 5MPa
IMPORTER:GlenDimplexFrance,7/10PorteNeuilly,12bd.DuMontd’Est,93160Noisy-Le-Grand,France
Touch Control LED Screen Yes Yes Yes
Continuous Drain Tube Yes, 2M Yes, 2M Yes, 2M
Handle Yes Yes Yes,
Timer Yes, 1-24h Yes, 1-24h Yes, 1-24h
Remote Control Yes Yes Yes
Condenser Yes Yes Yes
Number of Speed 3 3 3